The RP12-AR series DC/DC converters are designed for railway rolling stock applications with an extra wide continuous input voltage range of 36-160VDC (185VDC for 1s), making them suitable for 48V, 72V, 96V and 110VDC railway systems, but they are also suitable for non-railway high voltage battery applications. They have a built-in class A filter network and offer single or dual outputs from 3.3V up to +/-24V. The high efficiency permits an ambient temperature range from -40°C to +85°C without derating, forced cooling or the need for heatsinks. The RP12-AR series feature UVLO, OVP, SCP and OLP. This makes them ideal for many harsh railway and industrial applications such as powering IoT sensors, battery management systems or electric fork-lift trucks. The RP12-AR is available in an industry standard 1" x 1" package and comes with a 3 year warranty.
| Part Number | Power (W) | Isolation | Vin (V) | Main Vout (V) | Package Style | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 |   | RP12-11005SAR/N | 12 | Isolated | 36 - 160 | 4.5 to 5.5 | 1"x1" |  | ||||||
| 2 |   | RP12-11005SAR/P | 12 | Isolated | 36 - 160 | 4.5 to 5.5 | 1"x1" |  | ||||||
| 3 |   | RP12-11005SAR/XC | 12 | Isolated | 36 - 160 | 4.5 to 5.5 | 1"x1" |  | ||||||
| 4 |   | RP12-11012DAR/N | 12 | Isolated | 36 - 160 | ± 12 | 1"x1" |  | ||||||
| 5 |   | RP12-11012DAR/P | 12 | Isolated | 36 - 160 | ± 12 | 1"x1" |  | ||||||
| 6 |   | RP12-11012DAR/XC | 12 | Isolated | 36 - 160 | ± 12 | 1"x1" |  | ||||||
| 7 |   | RP12-11012SAR/N | 12 | Isolated | 36 - 160 | 10.8 to 13.2 | 1"x1" |  | ||||||
| 8 |   | RP12-11012SAR/P | 12 | Isolated | 36 - 160 | 10.8 to 13.2 | 1"x1" |  | ||||||
| 9 |   | RP12-11012SAR/XC | 12 | Isolated | 36 - 160 | 10.8 to 13.2 | 1"x1" |  | ||||||
| 10 |   | RP12-11015DAR/N | 12 | Isolated | 36 - 160 | ± 15 | 1"x1" |  | ||||||
| 11 |   | RP12-11015DAR/P | 12 | Isolated | 36 - 160 | ± 15 | 1"x1" |  | ||||||
| 12 |   | RP12-11015DAR/XC | 12 | Isolated | 36 - 160 | ± 15 | 1"x1" |  | ||||||
| 13 |   | RP12-11015SAR/N | 12 | Isolated | 36 - 160 | 13.5 to 18 | 1"x1" |  | ||||||
| 14 |   | RP12-11015SAR/P | 12 | Isolated | 36 - 160 | 13.5 to 18 | 1"x1" |  | ||||||
| 15 |   | RP12-11015SAR/XC | 12 | Isolated | 36 - 160 | 13.5 to 18 | 1"x1" |  | ||||||
| 16 |   | RP12-11024DAR/N | 12 | Isolated | 36 - 160 | ± 24 | 1"x1" |  | ||||||
| 17 |   | RP12-11024DAR/P | 12 | Isolated | 36 - 160 | ± 24 | 1"x1" |  | ||||||
| 18 |   | RP12-11024DAR/XC | 12 | Isolated | 36 - 160 | ± 24 | 1"x1" |  | ||||||
| 19 |   | RP12-11024SAR/N | 12 | Isolated | 36 - 160 | 21.6 to 28.8 | 1"x1" |  | ||||||
| 20 |   | RP12-11024SAR/P | 12 | Isolated | 36 - 160 | 21.6 to 28.8 | 1"x1" |  | ||||||
| 21 |   | RP12-11024SAR/XC | 12 | Isolated | 36 - 160 | 21.6 to 28.8 | 1"x1" |  | ||||||
| 22 |   | RP12-1103.3SAR/N | 12 | Isolated | 36 - 160 | 2.97 to 3.63 | 1"x1" |  | ||||||
| 23 |   | RP12-1103.3SAR/P | 12 | Isolated | 36 - 160 | 2.97 to 3.63 | 1"x1" |  | ||||||
| 24 |   | RP12-1103.3SAR/XC | 12 | Isolated | 36 - 160 | 2.97 to 3.63 | 1"x1" |  | 
| Attributes | RP12-AR | 
|---|---|
| AC/DC or DC/DC | DC/DC | 
| Power (W) | 12 | 
| Isolation | Isolated | 
| Vin (V) | 36 - 160 | 
| Isolation (kV) | 3 | 
| Mounting Type | THT | 
| Package Style | 1"x1" | 
| Length (mm) | 25.4 | 
| Width (mm) | 25.4 | 
| Height (mm) | 9.9 | 
| Certifications | CE, EN 50155, EN 55024, EN 55032, EN 60950-1, IEC 60950-1, UL 62368-1 | 
| MIN Operating Temp (°C) | -40 | 
| MAX Operating Temp (°C) | 100 | 
| Protections | OLP, OVP, SCP | 
| Directives | REACH, RoHS 2+ (10/10) | 
| Packaging Type | Tube | 
| Warranty | 3 Years | 
| Regulation | Regulated | 
| Part Number | Power (W) | Vout 1 (V) | Vin (V) | Mounting Type | |||||
|---|---|---|---|---|---|---|---|---|---|
| 1 |   | RP12-11005SAR/N | 12 | 5 | 36 - 160 | THT |  | ||
| 2 |   | RP12-11005SAR/P | 12 | 5 | 36 - 160 | THT |  | ||
| 3 |   | RP12-11005SAR/XC | 12 | 5 | 36 - 160 | THT |  | ||
| 4 |   | RP12-11012DAR/N | 12 | 12 | 36 - 160 | THT |  | ||
| 5 |   | RP12-11012DAR/P | 12 | 12 | 36 - 160 | THT |  | ||
| 6 |   | RP12-11012DAR/XC | 12 | 12 | 36 - 160 | THT |  | ||
| 7 |   | RP12-11012SAR/N | 12 | 12 | 36 - 160 | THT |  | ||
| 8 |   | RP12-11012SAR/P | 12 | 12 | 36 - 160 | THT |  | ||
| 9 |   | RP12-11012SAR/XC | 12 | 12 | 36 - 160 | THT |  | ||
| 10 |   | RP12-11015DAR/N | 12 | 15 | 36 - 160 | THT |  | ||
| 11 |   | RP12-11015DAR/P | 12 | 15 | 36 - 160 | THT |  | ||
| 12 |   | RP12-11015DAR/XC | 12 | 15 | 36 - 160 | THT |  | ||
| 13 |   | RP12-11015SAR/N | 12 | 15 | 36 - 160 | THT |  | ||
| 14 |   | RP12-11015SAR/P | 12 | 15 | 36 - 160 | THT |  | ||
| 15 |   | RP12-11015SAR/XC | 12 | 15 | 36 - 160 | THT |  | ||
| 16 |   | RP12-11024DAR/N | 12 | 24 | 36 - 160 | THT |  | ||
| 17 |   | RP12-11024DAR/P | 12 | 24 | 36 - 160 | THT |  | ||
| 18 |   | RP12-11024DAR/XC | 12 | 24 | 36 - 160 | THT |  | ||
| 19 |   | RP12-11024SAR/N | 12 | 24 | 36 - 160 | THT |  | ||
| 20 |   | RP12-11024SAR/P | 12 | 24 | 36 - 160 | THT |  | ||
| 21 |   | RP12-11024SAR/XC | 12 | 24 | 36 - 160 | THT |  | ||
| 22 |   | RP12-1103.3SAR/N | 12 | 3.3 | 36 - 160 | THT |  | ||
| 23 |   | RP12-1103.3SAR/P | 12 | 3.3 | 36 - 160 | THT |  | ||
| 24 |   | RP12-1103.3SAR/XC | 12 | 3.3 | 36 - 160 | THT |  | 
| 표제 | Type | 날짜 | 
|---|---|---|
| RP12-AR.pdf | Datasheet | 
| 표제 | Type | 날짜 | 
|---|---|---|
| The need for ultra-wide input range DC/DC converters | Blog Article | 2019. 7. 24 | 
| Railway Power Supplies | 2019. 5. 22 | |
| DC/DC Converters for On-board and Trackside Railway Applications | 2019. 3. 12 | |
| 가혹한 환경에 적합한 1"x1" 철도용 DC/DC 컨버터 | Official Press Release | 2019. 3. 7 | 
| 표제 | Type | 날짜 | 
|---|---|---|
| RPA: DC/DC Converters for Industry and Electromobility | Youtube Video | 2018. 3. 12 |