The RP40-FR series wide range input DC/DC converters have been especially designed for railway applications and are EN50155 certified. They are also certified to UL60950-1 and cUL 60950-1, this makes them ideal for all high input voltage telecom and industrial applications where approved safety standards are required.
| Part Number | Power (W) | Isolation | Vin (V) | Main Vout (V) | Package Style | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 
 
 | 
RP40-11005SFR/N
 | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 2 | 
 
 | 
RP40-11005SFR/N-HC
 | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 3 | 
 
 | 
RP40-11005SFR/P
 | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 4 | 
 
 | 
RP40-11005SFR/P-HC
 | 40 | Isolated | 43 - 160 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 5 | 
 
 | 
RP40-11012DFR/N
 | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" | 
 | ||||||
| 6 | 
 
 | 
RP40-11012DFR/N-HC
 | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" | 
 | ||||||
| 7 | 
 
 | 
RP40-11012DFR/P
 | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" | 
 | ||||||
| 8 | 
 
 | 
RP40-11012DFR/P-HC
 | 40 | Isolated | 43 - 160 | ± 12 | 2"x1" | 
 | ||||||
| 9 | 
 
 | 
RP40-11012SFR/N
 | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 10 | 
 
 | 
RP40-11012SFR/N-HC
 | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 11 | 
 
 | 
RP40-11012SFR/P
 | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 12 | 
 
 | 
RP40-11012SFR/P-HC
 | 40 | Isolated | 43 - 160 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 13 | 
 
 | 
RP40-11015DFR/N
 | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" | 
 | ||||||
| 14 | 
 
 | 
RP40-11015DFR/N-HC
 | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" | 
 | ||||||
| 15 | 
 
 | 
RP40-11015DFR/P
 | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" | 
 | ||||||
| 16 | 
 
 | 
RP40-11015DFR/P-HC
 | 40 | Isolated | 43 - 160 | ± 15 | 2"x1" | 
 | ||||||
| 17 | 
 
 | 
RP40-11015SFR/N
 | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 18 | 
 
 | 
RP40-11015SFR/N-HC
 | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 19 | 
 
 | 
RP40-11015SFR/P
 | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 20 | 
 
 | 
RP40-11015SFR/P-HC
 | 40 | Isolated | 43 - 160 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 21 | 
 
 | 
RP40-11024DFR/N
 | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" | 
 | ||||||
| 22 | 
 
 | 
RP40-11024DFR/N-HC
 | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" | 
 | ||||||
| 23 | 
 
 | 
RP40-11024DFR/P
 | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" | 
 | ||||||
| 24 | 
 
 | 
RP40-11024DFR/P-HC
 | 40 | Isolated | 43 - 160 | ± 24 | 2"x1" | 
 | ||||||
| 25 | 
 
 | 
RP40-11024SFR/N
 | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 26 | 
 
 | 
RP40-11024SFR/N-HC
 | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 27 | 
 
 | 
RP40-11024SFR/P
 | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 28 | 
 
 | 
RP40-11024SFR/P-HC
 | 40 | Isolated | 43 - 160 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 29 | 
 
 | 
RP40-1103.3SFR/N
 | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 30 | 
 
 | 
RP40-1103.3SFR/N-HC
 | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 31 | 
 
 | 
RP40-1103.3SFR/P
 | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 32 | 
 
 | 
RP40-1103.3SFR/P-HC
 | 40 | Isolated | 43 - 160 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 33 | 
 
 | 
RP40-2405SFR/N
 | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 34 | 
 
 | 
RP40-2405SFR/N-HC
 | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 35 | 
 
 | 
RP40-2405SFR/P
 | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 36 | 
 
 | 
RP40-2405SFR/P-HC
 | 40 | Isolated | 9 - 36 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 37 | 
 
 | 
RP40-2412DFR/N
 | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" | 
 | ||||||
| 38 | 
 
 | 
RP40-2412DFR/N-HC
 | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" | 
 | ||||||
| 39 | 
 
 | 
RP40-2412DFR/P
 | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" | 
 | ||||||
| 40 | 
 
 | 
RP40-2412DFR/P-HC
 | 40 | Isolated | 9 - 36 | ± 12 | 2"x1" | 
 | ||||||
| 41 | 
 
 | 
RP40-2412SFR/N
 | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 42 | 
 
 | 
RP40-2412SFR/N-HC
 | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 43 | 
 
 | 
RP40-2412SFR/P
 | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 44 | 
 
 | 
RP40-2412SFR/P-HC
 | 40 | Isolated | 9 - 36 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 45 | 
 
 | 
RP40-2415DFR/N
 | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" | 
 | ||||||
| 46 | 
 
 | 
RP40-2415DFR/N-HC
 | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" | 
 | ||||||
| 47 | 
 
 | 
RP40-2415DFR/P
 | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" | 
 | ||||||
| 48 | 
 
 | 
RP40-2415DFR/P-HC
 | 40 | Isolated | 9 - 36 | ± 15 | 2"x1" | 
 | ||||||
| 49 | 
 
 | 
RP40-2415SFR/N
 | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 50 | 
 
 | 
RP40-2415SFR/N-HC
 | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 51 | 
 
 | 
RP40-2415SFR/P
 | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 52 | 
 
 | 
RP40-2415SFR/P-HC
 | 40 | Isolated | 9 - 36 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 53 | 
 
 | 
RP40-2424DFR/N
 | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" | 
 | ||||||
| 54 | 
 
 | 
RP40-2424DFR/N-HC
 | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" | 
 | ||||||
| 55 | 
 
 | 
RP40-2424DFR/P
 | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" | 
 | ||||||
| 56 | 
 
 | 
RP40-2424DFR/P-HC
 | 40 | Isolated | 9 - 36 | ± 24 | 2"x1" | 
 | ||||||
| 57 | 
 
 | 
RP40-2424SFR/N
 | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 58 | 
 
 | 
RP40-2424SFR/N-HC
 | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 59 | 
 
 | 
RP40-2424SFR/P
 | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 60 | 
 
 | 
RP40-2424SFR/P-HC
 | 40 | Isolated | 9 - 36 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 61 | 
 
 | 
RP40-243.3SFR/N
 | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 62 | 
 
 | 
RP40-243.3SFR/N-HC
 | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 63 | 
 
 | 
RP40-243.3SFR/P
 | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 64 | 
 
 | 
RP40-243.3SFR/P-HC
 | 40 | Isolated | 9 - 36 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 65 | 
 
 | 
RP40-4805SFR/N
 | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 66 | 
 
 | 
RP40-4805SFR/N-HC
 | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 67 | 
 
 | 
RP40-4805SFR/P
 | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 68 | 
 
 | 
RP40-4805SFR/P-HC
 | 40 | Isolated | 18 - 75 | 4.5 to 5.5 | 2"x1" | 
 | ||||||
| 69 | 
 
 | 
RP40-4812DFR/N
 | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" | 
 | ||||||
| 70 | 
 
 | 
RP40-4812DFR/N-HC
 | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" | 
 | ||||||
| 71 | 
 
 | 
RP40-4812DFR/P
 | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" | 
 | ||||||
| 72 | 
 
 | 
RP40-4812DFR/P-HC
 | 40 | Isolated | 18 - 75 | ± 12 | 2"x1" | 
 | ||||||
| 73 | 
 
 | 
RP40-4812SFR/N
 | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 74 | 
 
 | 
RP40-4812SFR/N-HC
 | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 75 | 
 
 | 
RP40-4812SFR/P
 | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 76 | 
 
 | 
RP40-4812SFR/P-HC
 | 40 | Isolated | 18 - 75 | 10.8 to 13.2 | 2"x1" | 
 | ||||||
| 77 | 
 
 | 
RP40-4815DFR/N
 | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" | 
 | ||||||
| 78 | 
 
 | 
RP40-4815DFR/N-HC
 | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" | 
 | ||||||
| 79 | 
 
 | 
RP40-4815DFR/P
 | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" | 
 | ||||||
| 80 | 
 
 | 
RP40-4815DFR/P-HC
 | 40 | Isolated | 18 - 75 | ± 15 | 2"x1" | 
 | ||||||
| 81 | 
 
 | 
RP40-4815SFR/N
 | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 82 | 
 
 | 
RP40-4815SFR/N-HC
 | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 83 | 
 
 | 
RP40-4815SFR/P
 | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 84 | 
 
 | 
RP40-4815SFR/P-HC
 | 40 | Isolated | 18 - 75 | 13.5 to 18 | 2"x1" | 
 | ||||||
| 85 | 
 
 | 
RP40-4824DFR/N
 | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" | 
 | ||||||
| 86 | 
 
 | 
RP40-4824DFR/N-HC
 | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" | 
 | ||||||
| 87 | 
 
 | 
RP40-4824DFR/P
 | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" | 
 | ||||||
| 88 | 
 
 | 
RP40-4824DFR/P-HC
 | 40 | Isolated | 18 - 75 | ± 24 | 2"x1" | 
 | ||||||
| 89 | 
 
 | 
RP40-4824SFR/N
 | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 90 | 
 
 | 
RP40-4824SFR/N-HC
 | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 91 | 
 
 | 
RP40-4824SFR/P
 | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 92 | 
 
 | 
RP40-4824SFR/P-HC
 | 40 | Isolated | 18 - 75 | 21.6 to 28.8 | 2"x1" | 
 | ||||||
| 93 | 
 
 | 
RP40-483.3SFR/N
 | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 94 | 
 
 | 
RP40-483.3SFR/N-HC
 | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 95 | 
 
 | 
RP40-483.3SFR/P
 | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" | 
 | ||||||
| 96 | 
 
 | 
RP40-483.3SFR/P-HC
 | 40 | Isolated | 18 - 75 | 2.97 to 3.63 | 2"x1" | 
 | 
| Attributes | RP40-FR | 
|---|---|
| AC/DC or DC/DC | DC/DC | 
| Power (W) | 40 | 
| Isolation | Isolated | 
| Mounting Type | THT | 
| Package Style | 2"x1" | 
| Width (mm) | 25.4 | 
| MIN Operating Temp (°C) | -40 | 
| MAX Operating Temp (°C) | 60 | 
| Protections | OLP, OTP, OVP, SCP | 
| Directives | REACH, RoHS 2+ (10/10) | 
| Warranty | 3 Years | 
| Regulation | Regulated | 
| Part Number | Power (W) | Vout 1 (V) | Vin (V) | Mounting Type | |||||
|---|---|---|---|---|---|---|---|---|---|
| 1 | 
 
 | 
RP40-11005SFR/N
 | 40 | 5 | 43 - 160 | THT | 
 | ||
| 2 | 
 
 | 
RP40-11005SFR/N-HC
 | 40 | 5 | 43 - 160 | THT | 
 | ||
| 3 | 
 
 | 
RP40-11005SFR/P
 | 40 | 5 | 43 - 160 | THT | 
 | ||
| 4 | 
 
 | 
RP40-11005SFR/P-HC
 | 40 | 5 | 43 - 160 | THT | 
 | ||
| 5 | 
 
 | 
RP40-11012DFR/N
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 6 | 
 
 | 
RP40-11012DFR/N-HC
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 7 | 
 
 | 
RP40-11012DFR/P
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 8 | 
 
 | 
RP40-11012DFR/P-HC
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 9 | 
 
 | 
RP40-11012SFR/N
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 10 | 
 
 | 
RP40-11012SFR/N-HC
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 11 | 
 
 | 
RP40-11012SFR/P
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 12 | 
 
 | 
RP40-11012SFR/P-HC
 | 40 | 12 | 43 - 160 | THT | 
 | ||
| 13 | 
 
 | 
RP40-11015DFR/N
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 14 | 
 
 | 
RP40-11015DFR/N-HC
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 15 | 
 
 | 
RP40-11015DFR/P
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 16 | 
 
 | 
RP40-11015DFR/P-HC
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 17 | 
 
 | 
RP40-11015SFR/N
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 18 | 
 
 | 
RP40-11015SFR/N-HC
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 19 | 
 
 | 
RP40-11015SFR/P
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 20 | 
 
 | 
RP40-11015SFR/P-HC
 | 40 | 15 | 43 - 160 | THT | 
 | ||
| 21 | 
 
 | 
RP40-11024DFR/N
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 22 | 
 
 | 
RP40-11024DFR/N-HC
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 23 | 
 
 | 
RP40-11024DFR/P
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 24 | 
 
 | 
RP40-11024DFR/P-HC
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 25 | 
 
 | 
RP40-11024SFR/N
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 26 | 
 
 | 
RP40-11024SFR/N-HC
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 27 | 
 
 | 
RP40-11024SFR/P
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 28 | 
 
 | 
RP40-11024SFR/P-HC
 | 40 | 24 | 43 - 160 | THT | 
 | ||
| 29 | 
 
 | 
RP40-1103.3SFR/N
 | 40 | 3.3 | 43 - 160 | THT | 
 | ||
| 30 | 
 
 | 
RP40-1103.3SFR/N-HC
 | 40 | 3.3 | 43 - 160 | THT | 
 | ||
| 31 | 
 
 | 
RP40-1103.3SFR/P
 | 40 | 3.3 | 43 - 160 | THT | 
 | ||
| 32 | 
 
 | 
RP40-1103.3SFR/P-HC
 | 40 | 3.3 | 43 - 160 | THT | 
 | ||
| 33 | 
 
 | 
RP40-2405SFR/N
 | 40 | 5 | 9 - 36 | THT | 
 | ||
| 34 | 
 
 | 
RP40-2405SFR/N-HC
 | 40 | 5 | 9 - 36 | THT | 
 | ||
| 35 | 
 
 | 
RP40-2405SFR/P
 | 40 | 5 | 9 - 36 | THT | 
 | ||
| 36 | 
 
 | 
RP40-2405SFR/P-HC
 | 40 | 5 | 9 - 36 | THT | 
 | ||
| 37 | 
 
 | 
RP40-2412DFR/N
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 38 | 
 
 | 
RP40-2412DFR/N-HC
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 39 | 
 
 | 
RP40-2412DFR/P
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 40 | 
 
 | 
RP40-2412DFR/P-HC
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 41 | 
 
 | 
RP40-2412SFR/N
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 42 | 
 
 | 
RP40-2412SFR/N-HC
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 43 | 
 
 | 
RP40-2412SFR/P
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 44 | 
 
 | 
RP40-2412SFR/P-HC
 | 40 | 12 | 9 - 36 | THT | 
 | ||
| 45 | 
 
 | 
RP40-2415DFR/N
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 46 | 
 
 | 
RP40-2415DFR/N-HC
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 47 | 
 
 | 
RP40-2415DFR/P
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 48 | 
 
 | 
RP40-2415DFR/P-HC
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 49 | 
 
 | 
RP40-2415SFR/N
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 50 | 
 
 | 
RP40-2415SFR/N-HC
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 51 | 
 
 | 
RP40-2415SFR/P
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 52 | 
 
 | 
RP40-2415SFR/P-HC
 | 40 | 15 | 9 - 36 | THT | 
 | ||
| 53 | 
 
 | 
RP40-2424DFR/N
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 54 | 
 
 | 
RP40-2424DFR/N-HC
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 55 | 
 
 | 
RP40-2424DFR/P
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 56 | 
 
 | 
RP40-2424DFR/P-HC
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 57 | 
 
 | 
RP40-2424SFR/N
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 58 | 
 
 | 
RP40-2424SFR/N-HC
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 59 | 
 
 | 
RP40-2424SFR/P
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 60 | 
 
 | 
RP40-2424SFR/P-HC
 | 40 | 24 | 9 - 36 | THT | 
 | ||
| 61 | 
 
 | 
RP40-243.3SFR/N
 | 40 | 3.3 | 9 - 36 | THT | 
 | ||
| 62 | 
 
 | 
RP40-243.3SFR/N-HC
 | 40 | 3.3 | 9 - 36 | THT | 
 | ||
| 63 | 
 
 | 
RP40-243.3SFR/P
 | 40 | 3.3 | 9 - 36 | THT | 
 | ||
| 64 | 
 
 | 
RP40-243.3SFR/P-HC
 | 40 | 3.3 | 9 - 36 | THT | 
 | ||
| 65 | 
 
 | 
RP40-4805SFR/N
 | 40 | 5 | 18 - 75 | THT | 
 | ||
| 66 | 
 
 | 
RP40-4805SFR/N-HC
 | 40 | 5 | 18 - 75 | THT | 
 | ||
| 67 | 
 
 | 
RP40-4805SFR/P
 | 40 | 5 | 18 - 75 | THT | 
 | ||
| 68 | 
 
 | 
RP40-4805SFR/P-HC
 | 40 | 5 | 18 - 75 | THT | 
 | ||
| 69 | 
 
 | 
RP40-4812DFR/N
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 70 | 
 
 | 
RP40-4812DFR/N-HC
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 71 | 
 
 | 
RP40-4812DFR/P
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 72 | 
 
 | 
RP40-4812DFR/P-HC
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 73 | 
 
 | 
RP40-4812SFR/N
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 74 | 
 
 | 
RP40-4812SFR/N-HC
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 75 | 
 
 | 
RP40-4812SFR/P
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 76 | 
 
 | 
RP40-4812SFR/P-HC
 | 40 | 12 | 18 - 75 | THT | 
 | ||
| 77 | 
 
 | 
RP40-4815DFR/N
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 78 | 
 
 | 
RP40-4815DFR/N-HC
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 79 | 
 
 | 
RP40-4815DFR/P
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 80 | 
 
 | 
RP40-4815DFR/P-HC
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 81 | 
 
 | 
RP40-4815SFR/N
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 82 | 
 
 | 
RP40-4815SFR/N-HC
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 83 | 
 
 | 
RP40-4815SFR/P
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 84 | 
 
 | 
RP40-4815SFR/P-HC
 | 40 | 15 | 18 - 75 | THT | 
 | ||
| 85 | 
 
 | 
RP40-4824DFR/N
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 86 | 
 
 | 
RP40-4824DFR/N-HC
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 87 | 
 
 | 
RP40-4824DFR/P
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 88 | 
 
 | 
RP40-4824DFR/P-HC
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 89 | 
 
 | 
RP40-4824SFR/N
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 90 | 
 
 | 
RP40-4824SFR/N-HC
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 91 | 
 
 | 
RP40-4824SFR/P
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 92 | 
 
 | 
RP40-4824SFR/P-HC
 | 40 | 24 | 18 - 75 | THT | 
 | ||
| 93 | 
 
 | 
RP40-483.3SFR/N
 | 40 | 3.3 | 18 - 75 | THT | 
 | ||
| 94 | 
 
 | 
RP40-483.3SFR/N-HC
 | 40 | 3.3 | 18 - 75 | THT | 
 | ||
| 95 | 
 
 | 
RP40-483.3SFR/P
 | 40 | 3.3 | 18 - 75 | THT | 
 | ||
| 96 | 
 
 | 
RP40-483.3SFR/P-HC
 | 40 | 3.3 | 18 - 75 | THT | 
 | 
| Title | Type | Date | 
|---|---|---|
| RP40-FR.pdf | Datasheet | 
| Title | Type | Date | 
|---|---|---|
| Power Supplies for Railway Data Communications | Blog Article | Aug 26, 2022 | 
| Rugged High-Power Converters Meet Stringent Railway Standards | Blog Article | Jul 15, 2022 | 
| The need for ultra-wide input range DC/DC converters | Blog Article | Jul 24, 2019 | 
| Railway Power Supplies | May 22, 2019 | |
| DC/DC Converters for On-board and Trackside Railway Applications | Mar 12, 2019 | 
| Title | Type | Date | 
|---|---|---|
| RPA: DC/DC Converters for Industry and Electromobility | Youtube Video | Mar 12, 2018 |